Boiler charts

Pulverised fuel fired, once through, steam boilers

The achievement of high steam generation efficiency values required the complete modification of boiler steam - water system, when compared with drum system. Due to the licence acquired from Sulzer, RAFAKO became a leading manufacturer of such boilers, even though the number of lignite fired boilers was significantly smaller than the number of hard coal fired ones. Opole Power Plant with its four BP-1150 boilers is our major reference within this field.


BACK TO THE LIST OF TYPES OF BOILERS
produkt
Boiler type: Once-through
Firing method: Tangential
Max. continuous rating: 285 kg/s
Live steam temperature outlet: 540°C
Live steam pressure outlet: 178 MPa
Reheat steam temperature inlet/outlet: 330/540°C
Reheat steam pressure inlet: 36,3 MPa
Feedwater temperature: 275°C
Fuel type: Bituminous coal
Additional informations: Steam boiler
Instalacje: TAIYUAN Power Plant China. Boiler 2 x BP - 1025 t/h. Btuminous coal. Delivery Year 1989.

Galeria zdjęć

produkt
Boiler type: Once-through
Firing method: Tangential
Max. continuous rating: 320 kg/s
Live steam temperature outlet: 540°C
Live steam pressure outlet: 18,3 MPa
Reheat steam temperature inlet/outlet: 335/540°C
Reheat steam pressure inlet: 4,2 MPa
Feedwater temperature: 255°C
Gross efficiency: 91,7%
Fuel type: Bituminous coal
Net calorific value: 23 MJ/kg
Additional informations: Steam boiler
Instalacje: OPOLE Power Plant

Galeria zdjęć

produkt