Pulverised fuel hot water boilers

Pulverised fuel fired, hot water boilers are highly specific for Polish heat generating sector. They were constructed mainly in Sixties and Seventies, when cogeneration was not an absolute economic requirement. Although these boilers are meant only for district heating or supply of hot process water, they are very numerous and almost all were manufactured by RAFAKO. The largest among them, WP-200 type boilers have a capacity of 200 Gcal/h (233 MW).


BACK TO THE LIST OF TYPES OF BOILERS
produkt
Boiler type: Forced flow
Firing method: Tangential
Max. continuous rating: 233 MW
Water temperature inlet/outlet: 115/160°C
Water pressure inlet/outlet: 2,5 MPa
Gross efficiency: 87%
Fuel type: Bituminous coal
Net calorific value: 19,7 MJ/kg
Additional informations: Hot water boiler
Instalacje: SIEKIERKI CHP Plant
KATOWICE - DĄBRÓWKA CHP Plant
KAWĘCZYN CHP Plant

Galeria zdjęć

produkt
Boiler type: Forced flow
Firing method: Tangential
Max. continuous rating: 81 MW
Water temperature inlet/outlet: 70/155°C
Water pressure inlet/outlet: 2,5 MPa
Gross efficiency: 84%
Fuel type: Bituminous coal
Net calorific value: 21 MJ/kg
Additional informations: Hot water boiler
Instalacje: BIAŁYSTOK CHP Plant
ŁAGISZA Power Plant
Kraków CHP Plant
WROCŁAW CHP Plant
GDAŃSK CHP Plant
GORZÓW CHP Plant
BĘDZIN CHP Plant
GLIWICE CHP Plant
LUBLIN CHP Plant
STALOWA WOLA Power Plant
„TARNÓW” Chemical Plant
EC Synthos Dwory Oświęcim
KWK „ZOFIÓWKA” CHP Plant
LUBLIN Truck Factory

Galeria zdjęć