OFFER
References
BEŁCHATÓW Power Plant
Rogowiec
Installed dust extraction equipment:
Heat or electricity power | Boiler number | Flue gas flow [m^3/h] | Guaranteed emission [mg/m^3] | Fuel | Start-up Year |
---|---|---|---|---|---|
370 MW | K4 | 2 050 000 | <50 | lignite | 2009 |
360 MW | K5 i K6 | 2 x 2 050 000 | <50 | lignite | 2011 |
Installed boilers:
Boiler Type | Qty | Capacity [t/h] /Output Power [MW] | Steam Temperature [oC] | Steam Pressure [MPa] | Fuel | Start-up Year |
---|---|---|---|---|---|---|
BB | 12 | 1150 t/h | 540/540 | 18,3/4,2 | lignite | 1982 - 1988 |
BB | 1 | 2400 t/h | 554/582 | 26,6/5,4 | lignite | 2012 |
Installed FGD plants:
Boiler | Thermal or electric output | Flue gas quantity [mn3/h] | Sulphur content in fuel in % | Desulphurisation efficiency in % | Absorbent | Final product | Start-up Year |
---|---|---|---|---|---|---|---|
K5, K6 | 2 x 360 MWel | 2 x 2 100 000 | 0,75 max 1,2 | 93 | limestone | gypsum | 2000 |
K7, K9 | 2 x 360 MWel | 2 x 2 100 000 | 0,75 max 1,2 | 95 | limestone | gypsum | 2003 |
K3, K4 | 2 x 360 MWel | 2 x 2 100 000 | 0,6 max 1,85 | 95 | limestone | gypsum | 2007 |
K8, K10, K11, K12 | 4 x 370 MWel | 2 x 2 100 000 | 1,2 max 1,85 | 95 | limestone | gypsum | 2011 |
BB-2400 | 858 MWel | 2 x 1 800 000 | 1,2 max 1,85 | 96 | limestone powder | gypsum | 2011 |
K1, K2 | 2 x 360 MWel | 2 400 000 | 1,2 max 1,85 | 96 | limestone | gypsum | 2012 |
2007 - Expansion of the gypsum storage site
2014 - Modernisation of the flue gas desulphurisation plants for Units No. 5 and 6
2016 - Modernisation and overhaul of the flue gas heating system for Units No. 8, 10, 11 and 12
BACK TO THE MAP OF IMPLEMENTATIONS